rem UPDSHELL.TXT rem rem Sample of a shell update/upgrade batch routine used to upgrade rem workstations to the version/date-stamps specified in the command rem parameter list. rem This batch file (once converted from text), can be called from a rem a login script file or another batch process. rem rem As sampled from the original shell update/upgrade routine written rem by Terry Bergman at Toshiba America Info Sys Inc (714) rem rem rem Parameter list when calling this batch file rem rem 1st = Minimum IPX version number ei. 3.10 rem batch file will attempt to upgrade workstation if IPX rem version is less than specified IPX version number rem 2nd = Minimum IPX.COM date stamp ei. 03/01/92 rem batch file will attempt to upgrade workstation if IPX.COM rem file's date stamp is earlier than specified date. rem 3rd = Minimum NETX version number ei. 3.22 rem batch file will attempt to upgrade workstation if NETX rem version is less than specified NETX version number rem 4th = Minimum NETX.COM data stamp ei. 03/01/92 rem batch file will attempt to upgrade workstation if NETX.COM rem file's date stamp is earlier than specified date. rem rem SET UPGRADE = NONE Echo Checking IPX and NETX versions. Please wait ... IF EXIST C:\NETWORK\IPX.COM GOTO SHELLCHECK echo No C:\NETWORK directory NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "No C:\NETWORK directory" /s GOTO ERROR :SHELLCHECK IF EXIST C:\NETWORK\SHELL.CFG GOTO NETXCHECK echo No C:\NETWORK\SHELL.CFG file NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "No C:\NETWORK\SHELL.CFG file" /s GOTO ERROR :NETXCHECK IF EXIST C:\NETWORK\NETX.COM GOTO BATCHECK echo No C:\NETWORK\NETX.COM file NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "No C:\NETWORK\NETX.COM file" /s GOTO ERROR :BATCHCHECK IF EXIST C:\NETWORK\NETWORK.BAT GOTO IPXVER echo No C:\NETWORK\NETWORK.BAT file NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "No C:\NETWORK\NETWORK.BAT file" /s GOTO ERROR rem Check IPX version in memory. If the version number is the same or rem greater than specified, skip IPX card checking and goto NETX stuff rem :IPXVER NCMPDRVR %1 IPX >NUL IF ERRORLEVEL 1 GOTO NETXVER echo Analyzing IPX.COM for upgrade. Please wait... SET UPGRADE = IPX :NIC1 NSTRING "Ungermann-Bass PCNIU/Token Ring Version 2.4" C:\NETWORK\IPX.COM >NUL IF NOT ERRORLEVEL 1 GOTO NIC2 NCMPDATE C:\NETWORK\IPX.COM %2 >NUL IF ERRORLEVEL 1 GOTO IPXERROR COPY X:\PUBLIC\NETDRVRS\UBDRVRS\TRING\PCNIU\*.* C:\NETWORK GOTO NETXVER :NIC2 NSTRING "Olicom Token-Ring 16/4 V1.10" C:\NETWORK\IPX.COM >NUL IF NOT ERRORLEVEL 1 GOTO NIC99 NCMPDATE C:\NETWORK\IPX.COM %2 >NUL IF ERRORLEVEL 1 GOTO IPXERROR COPY X:\PUBLIC\NETDRVRS\UBDRVRS\TRING\ISA164\*.* C:\NETWORK GOTO NETXVER rem and so on for the rest of the cards rem For this demonstration, we'll say that there are only 2 different rem cards at this site. :NIC99 echo Unknown Network Card. Cannot complete upgrade. NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "Unknown Network Card" /S SET UPGRADE = NONE GOTO ERROR :IPXERROR NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "IPX loaded from different directory" /S SET UPGRADE = NONE :NETXVER IF %UPGRADE% == IPX NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "IPX Upgraded" /S NCMPDRVR %3 NETX >NUL IF ERRORLEVEL 1 GOTO LOGOUT NCMPDATE C:\NETWORK\NETX.COM %4 >NUL IF ERRORLEVEL 1 GOTO NETXERROR COPY X:\PUBLIC\NETDRVRS\NETX.COM C:\NETWORK\*.* NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "Upgraded NETX" /S SET UPGRADE = NETX GOTO LOGOUT :NETXERROR NLOGMSG X:\USER\UPDATE\UPGRADE.LOG "NETX loaded from different directory" /S GOTO LOGOUT :ERROR echo echo YOUR WORKSTATION CANNOT BE AUTOMATICALLY UPGRADED ! echo PLEASE REPORT THIS TO YOUR LAN ADMINISTRATOR ! echo GOTO END :LOGOUT IF %UPGRADE% == NONE GOTO END echo echo YOU MUST REBOOT IN ORDER TO ACTIVATE YOUR NEW DRIVERS. echo SET UPGRADE= SET NIC= PAUSE LOGOUT :END SET UPGRADE= SET NIC= rem Finis